Aaron Riedel
ceed3ed4bd
All checks were successful
continuous-integration/drone/push Build is passing
123 lines
5.4 KiB
YAML
123 lines
5.4 KiB
YAML
---
|
|
apiVersion: monitoring.coreos.com/v1
|
|
kind: PrometheusRule
|
|
metadata:
|
|
name: prometheus-core-deployment-rules
|
|
namespace: prometheus
|
|
labels:
|
|
monitor: core-deployment
|
|
spec:
|
|
groups:
|
|
- name: hardware
|
|
rules:
|
|
- alert: MemoryHigh
|
|
expr: round((((node_memory_MemTotal_bytes - node_memory_MemAvailable_bytes) / node_memory_MemTotal_bytes) * 100), 0.1) > 80
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: "Memory over 80%"
|
|
description: "Memory on node {{ $labels.node }} is over 80% for more than 5 minutes. Plox fix. Memory usage: {{ $value }}%"
|
|
- alert: DiskspaceLow
|
|
expr: round(node_filesystem_avail_bytes{mountpoint="/"} / node_filesystem_size_bytes{mountpoint="/"} * 100, 1) < 5
|
|
for: 1m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: "Free disk space at {{ $value }}%"
|
|
description: "Disk space on node {{ $labels.node }} is only {{ $value }}%. Plox fix. Partition: {{ $labels.device }}"
|
|
- alert: HostMemoryUnderMemoryPressure
|
|
expr: rate(node_vmstat_pgmajfault[1m]) > 1000
|
|
for: 2m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host memory under memory pressure {{ $labels.node }}
|
|
description: "The node is under heavy memory pressure. High rate of major page faults\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
|
- alert: HostUnusualDiskReadRate
|
|
expr: sum by (instance) (rate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 200
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host unusual disk read rate {{ $labels.node }}
|
|
description: "Disk is probably reading too much data (> 200 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
|
- alert: HostUnusualDiskWriteRate
|
|
expr: sum by (instance) (rate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 200
|
|
for: 3m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host unusual disk write rate {{ $labels.node }}
|
|
description: "Disk is probably writing too much data (> 200 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
|
- alert: HostCpuStealNoisyNeighbor
|
|
expr: avg by(instance) (rate(node_cpu_seconds_total{mode="steal"}[5m])) * 100 > 10
|
|
for: 1m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host CPU steal noisy neighbor {{ $labels.node }}
|
|
description: "CPU steal is > 10%. A noisy neighbor is killing VM performances or a spot instance may be out of credit.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
|
- alert: HostPhysicalComponentTooHot
|
|
expr: node_hwmon_temp_celsius > 90
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: Host physical component too hot {{ $labels.node }}
|
|
description: "Physical hardware component too hot\n Sensor = {{ $labels.sensor }}\n Temp = {{ $value }}"
|
|
- alert: SMARTbad
|
|
expr: smartmon_device_smart_healthy < 1
|
|
for: 0m
|
|
labels:
|
|
severity: critical
|
|
annotations:
|
|
summary: SMART check bad of drive {{ $labels.exported_disk }} in node {{ $labels.node }}
|
|
description: "SMART check returned bad health of {{ $labels.exported_disk }} in node {{ $labels.node }}. VALUE = {{ $value }}\n LABELS = {{ $labels }}"
|
|
- alert: "SMARTcheck too old"
|
|
expr: (time() - smartmon_smartctl_run) > 10800
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: "SMARTcheck not running"
|
|
description: 'The last SMARTcheck on node {{ $labels.node }} was more than 3h ago. Plox fix.'
|
|
- alert: "ECC Memory errors"
|
|
expr: (node_edac_correctable_errors_total) > 100
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: "ECC errors on {{ $labels.node }}"
|
|
description: 'The node {{ $labels.node }} accumulated {{ $value }} correctable errors.'
|
|
- alert: "ECC Memory uncorrectable errors"
|
|
expr: (node_edac_uncorrectable_errors_total) > 0
|
|
labels:
|
|
severity: critical
|
|
annotations:
|
|
summary: "ECC errors on {{ $labels.node }}"
|
|
description: 'The node {{ $labels.node }} accumulated {{ $value }} uncorrectable errors.'
|
|
- name: etcdbackup
|
|
rules:
|
|
- alert: "etcdbackup too old"
|
|
expr: (time() - etcdbackup_time) > 10800
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: "etcd backup not running"
|
|
description: 'The last etcd backup on node {{ $labels.node }} was more than 3h ago. Plox fix.'
|
|
- alert: "etcdbackup failed"
|
|
expr: etcdbackup_result > 0
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: "etcdbackup failed"
|
|
description: "The backup script for etcd failed on node {{ $labels.node }}. Plox fix."
|
|
- name: kubernetes
|
|
rules:
|
|
- alert: KubernetesUnhealthyPod
|
|
expr: kube_pod_container_status_waiting_reason == 1
|
|
for: 5m
|
|
labels:
|
|
severity: warning
|
|
annotations:
|
|
summary: "The Pod {{ $labels.pod }} is {{ $labels.reason }}"
|
|
description: "The Pod {{ $labels.pod }} is in the state {{ $labels.reason }} for more than 5m. The Pod is in namespace {{ $labels.namespace }} and on node {{ $labels.node }}."
|